Where do energy savings in a company begin?

Your company’s energy consumption keeps rising, even though production volume remains similar. Or you have had a weaker month or even a shutdown, but the expected drop in consumption did not happen. From the invoices, you can see how much energy the company used and how much it paid for it. However, you still do not know what is driving consumption up, which part of it is essential and where unnecessary losses occur. Without this information, it is difficult to find where to save without limiting production. Energy savings in a company therefore begin with measurement that you link to the production status and verify in a small pilot.

Kde začína úspora energie vo firme? | Where do energy savings in a company begin?

An invoice will not tell you where energy is leaking

On the invoice, you see the total for the whole month, not the causes of consumption. The invoice combines full production, downtime, weekends and shutdowns into a single number. A drop in costs therefore does not necessarily mean better management if the company produced less, changed its product mix or bought energy at a different price. Outdoor temperature, in turn, changes the need for heating and cooling regardless of how well the operation runs. Real electricity savings therefore only occur when you need less electricity for the same production output. And this can only be verified by measurement.

So what do you need instead of an invoice?

✅ Start by metering the main feeders

First of all, you need to see where and when the company uses electricity. You do not have to meter every machine. That could make your project unnecessarily large before you know which data you will actually use. At the start, submetering the main feeders is enough. A feeder is the part of the distribution system that supplies one hall or technology, and a submeter measures only that feeder. The main meter then shows you the load profile of the entire plant, and the submeters tell you where the load comes from and which part has higher consumption than you would expect.

✅ Link consumption to what was happening in production

However, the consumption figure on its own does not tell you whether it is acceptable. If a hall draws a lot of electricity during full production, that is normal. If it draws a similar amount on a Sunday, when nobody is working there, something is running unnecessarily. That is why you should record alongside consumption what was happening at that moment, meaning whether production was running, whether it was stopped, or whether it was a weekend or a shutdown. For heating and cooling, add the outdoor temperature, because in a cold month the company naturally uses more energy for heating.

✅ Monitor data in one place

To collect and monitor this data, it pays to implement an EMS, an energy management system. An EMS stores consumption from individual meters, displays it in charts and allows you to compare it with the previous week, month or year. If you connect it to a SCADA system, which collects data directly from the machines, and to an MES, which records the course of production, you will see consumption and what was happening in production on a single screen. You no longer have to manually combine data from meters and from production.

What energy saving tips will the measured data reveal?

⚠️ Consumption does not drop even when nothing is being produced

Once you can see consumption, look at nights and weekends first. If a feeder draws a lot of electricity even when nothing is being produced, you know where to look. Find the equipment in that part of the operation that was left switched on. Some of it has to run, for example servers, security systems or technology that must be kept at a constant temperature. Other equipment runs unnecessarily because nobody switched it off after production ended. For each piece of equipment, decide separately whether it has to run or whether you can switch it off or put it into energy-saving mode.

⚠️ Pumps and fans run at full speed unnecessarily

In industry, most electricity is consumed by electric motors that drive pumps, fans and compressors. You can recognize this in the data when consumption stays the same during full production and when less is being produced. The solution is usually speed control based on actual demand. However, a variable frequency drive, the device used for speed control, is not enough on its own if it is not set up correctly. The lower limit is determined by process requirements, such as minimum cooling flow or required extraction, so identify them before you start changing settings.

⚠️ Compressed air consumes energy too

With compressed air, energy is most often lost in three ways:

  • Air leaks through leaky hoses and joints.
  • Air also flows into parts of the distribution system that nobody uses anymore.
  • Compressors run more than production needs.

Depending on what you find, you can repair leaks, disconnect unused parts of the distribution system or set up the compressors so that they alternate better. When air demand is lower, one compressor can even be switched off completely. Lower pressure means lower electricity consumption, but for a machine that needs higher pressure, it can slow down work or cause product defects. Reduce pressure carefully and verify that all machines work properly even when air usage in production is at its highest.

⚠️ Unnecessary heating, cooling and ventilation

Heating, cooling and ventilation most often waste energy when their settings do not match each other. It may happen that in one room the heating is on while the air conditioning is cooling at the same time, because each unit is set to a different temperature. Morning start-up can also reveal unnecessary consumption. If the building starts heating before people arrive, that is fine. However, if it is heated even during a public holiday, when nobody is at work, the schedule is set incorrectly.

⚠️ Downtime and defects consume energy too

During downtime, a machine waiting for material often continues heating, cooling or maintaining hydraulic pressure. On the energy chart, this kind of downtime looks like production, even though no good units are being added. Only when you link consumption to the machine status do you find out how long such waiting lasts. The solution may be to eliminate the cause of the waiting or to use an energy-saving mode during longer breaks. When deciding, you need to consider the energy and time needed for restart as well as quality requirements, which is why a complete shutdown during a short stop is often not worth it.

How does data turn into specific electricity savings?

💡 Set up alerts that make it clear what is happening

Measurement alone does not save energy. Energy savings in a company only occur when someone responds to the findings. That is why it pays to set up alerts so that it is clear exactly what is happening. An alert saying “high consumption” does not tell you what to check. A more useful alert is one stating that a production feeder is out of operation, but its load remains above the usual value for longer than allowed. Start with just a few alerts for the largest loads, because if there are too many, people will gradually stop reading them.

💡 Decide who handles the alert

Such an alert also needs a specific person to handle it, for example maintenance or the shift supervisor. That person identifies the cause, decides on the action and checks whether the deviation has disappeared. For each resolved alert, it is good practice to record what the cause was and what was done. When the same problem comes back, these records show you right away whether it is a one-off error or something that needs a permanent solution. Without a designated owner, measurement becomes just a list of recurring problems.

💡 Leave building settings to the BMS

Who takes action and where depends on what the data shows. If it is a machine that was left switched on, maintenance or the operators deal with it. For heating, cooling and ventilation, you do not have to set up each unit separately. This is what a BMS is for, as it controls them from one place. In it, you set schedules and temperatures for each space according to its needs, and the BMS then maintains them on its own. With such an automatic rule, you need to keep production requirements in mind and determine what should happen when some data is missing.

What should energy savings in a company look like step by step?

1️⃣ Choose the place with the clearest unnecessary consumption

As a first step, choose a place where the data shows unnecessary consumption that lasts a long time and has a clear cause. This may be, for example, a compressor room that draws electricity even over the weekend, when nobody uses the air. Smaller consumption that lasts thousands of hours a year can save more than a short, high peak. At the same time, make sure the intervention will not put production at risk, meaning quality, speed or machine reliability. The first project should be safe and easy to verify, because you will base decisions about further projects on its results.

2️⃣ Verify the cause and the savings with a pilot

Run a pilot at the selected location, meaning a small-scale trial project. In the case of a compressor room, the pilot will show you why it runs over the weekend and how much consumption can be eliminated without production running short of air. Before the intervention, decide who will lead the pilot, what must not get worse in production and how you will compare consumption before and after the intervention. Let the pilot run long enough to capture normal weeks with weekends as well as periods of higher and lower production, otherwise a single unusual week can distort the result.

3️⃣ Calculate the benefit and roll out the approach

From the pilot, you get two numbers: how much the load drops and how many hours a year this applies to. Multiplying them gives you the annual savings. For example, if after the adjustment the compressors draw 8 kW less for 2,000 hours a year, the electricity savings will be 16,000 kWh per year. These electricity savings can then be multiplied by the price from your invoice and compared with the cost of the measure. If the pilot confirms the savings, you can apply the same approach to other halls or technologies, and you will already know what metering and settings they will need.

Let’s find energy saving opportunities in your operation too

If you want to know where it makes sense to start in your production, the first step is a no-obligation consultation, followed by an assessment of the metering and data you already have. Together, we will find out which meters and systems can be used, what is missing to explain consumption and where it is worth running a pilot. Before any larger investment, you will know what to measure, what to connect and where to start. IoT Industries will help you connect your EMS with production and building data so that energy savings in your company are based on verified numbers, not estimates.

Why Choose IoT/IIoT Implementation with IoT Industries?

Traditional companies typically specialize in OT (operational technologies, such as production lines and devices) or classic enterprise IT systems. However, we are able to connect both of these worlds. Our unique expertise in integrating OT and IT allows us to deliver innovative solutions in digital transformation, enhancing efficiency, reliability, and competitiveness for manufacturing companies.

Comments are closed.